PRODUCT DETAILS
**A general rule for compressor output is 3-5 SCFM per HP. Check in your compressor manual, or with the manufacturer**
MHL Mini Heatless Regenerative Dryers provide extremely dry air for point of use and low flow applications. These compressed air dryers are simple to install, and easy to maintain. They deliver a -40°F pressure dew point to protect pneumatic equipment and processes from the harmful and costly effects of compressed air moisture. In critical applications, MHL Series dryers can deliver a -100°F pressure dew point.
FEATURES AND BENEFITS
- 35 SCFM @ 100 PSIG
- Solid state timer with LED display for visual monitoring and built-in timer memory
- Low air velocity through the desiccant bed for efficient drying
- Large internal air passages to minimize pressure drop
- Only 8 threaded components, 75% fewer potential leak points than competitive brands
- Easily serviceable components
- NEMA 4 electrical rating is standard
- Moisture indicator
- Tower pressure gauges
APPLICATIONS
- Air bearings
- Air brushings
- Air operated pumps
- Air turbines
- Cable pressurization
- Car wash controls
- Dental offices
- Gas chromatographs
- Graphic printers
- Laboratory instruments
- Point-of-use drying for pneumatic tools and processes
MHL-3 | MHL-6 | MHL-9 | MHL-12 | MHL-16 | MHL-25 | MHL-35 | MHL-50 | |||||||||||||
Flows (SCFM) at 100 PSIG | ||||||||||||||||||||
Inlet Flow | 3 | 6 | 9 | 12 | 16 | 25 | 35 | 50 | ||||||||||||
Purge Flow | 0.8 | 1.6 | 2.4 | 3.2 | 3.4 | 5.4 | 7.8 | 10.8 | ||||||||||||
Outlet Flow | 2.2 | 4.4 | 6.6 | 8.8 | 12.6 | 19.6 | 27.2 | 39.2 | ||||||||||||
*Flows (SCFM) at 150 PSIG | ||||||||||||||||||||
Inlet Flow | 4.2 | 8.4 | 12.9 | 17.2 | 22.5 | 35.9 | 50.3 | 71.9 | ||||||||||||
Purge Flow | 0.8 | 1.5 | 2.4 | 3.3 | 3.4 | 5.5 | 8 | 11.1 | ||||||||||||
Outlet Flow | 3.4 | 6.9 | 10.5 | 13.9 | 19.1 | 30.4 | 42.3 | 60.8 | ||||||||||||
*Flows (SCFM) at 50 PSIG | ||||||||||||||||||||
Inlet Flow | 1.7 | 3.4 | 5.1 | 6.8 | 9 | 14.1 | 19.6 | 28.2 | ||||||||||||
Purge Flow | 0.7 | 1.4 | 2.1 | 2.8 | 3 | 4.8 | 7.7 | 9.7 | ||||||||||||
Outlet Flow | 1 | 2 | 3 | 4 | 6 | 9.3 | 11.9 | 18.5 | ||||||||||||
*with orifice change | ||||||||||||||||||||
Additional Specifications | ||||||||||||||||||||
Inlet / Outlet Ports | 3/8" | 1/2" | ||||||||||||||||||
Power Requirements | 115 VAC, Single Phase, 50/60 Hz or 230 VAC, Single Phase, 50/60 Hz | |||||||||||||||||||
Maximum Temperature | 120°F ambient | |||||||||||||||||||
Maximum Pressure | 150 PSIG | |||||||||||||||||||
Outlet Dew Point | -40°F pressure dew point (PDP) with 100°F saturated inlet | |||||||||||||||||||
Weight | 8 lbs | 9 lbs | 10 lbs | 11 lbs | 29 lbs | 34 lbs | 59 lbs | 65 lbs | ||||||||||||
Dimensions | ||||||||||||||||||||
H | W | D | P | A | B | |||||||||||||||
MHL-3 | 13.6" | 7.4" | 5.2" | 9.3" | 5.8" | 2.8" | ||||||||||||||
MHL-6 | 18.2" | 7.4" | 5.2" | 13" | 5.8" | 2.8" | ||||||||||||||
MHL-9 | 17.3" | 7.4" | 5.2" | 12.1" | 5.8" | 2.8" | ||||||||||||||
MHL-12 | 21.1" | 7.4" | 5.2" | 14.9" | 5.8" | 2.8" | ||||||||||||||
MHL-16 | 33" | 9.5" | 6.5" | 20.7" | 7" | 23.6" | ||||||||||||||
MHL-25 | 41.9" | 9.5" | 6.5" | 29.6" | 7" | 32.4" | ||||||||||||||
MHL-35 | 39.3" | 10" | 7" | 26.5" | 9" | 30.1" | ||||||||||||||
MHL-50 | 46.3" | 10" | 7" | 33.5" | 9" | 37.1" | ||||||||||||||
|
Downloads