With the nano NMG membrane gas generators, you can effortlessly and inexpensively produce nitrogen in-house. This is made possible by its simple and proven membrane technology, which separates nitrogen from the air without requiring any moving parts or electricity. The best part? You can achieve a rapid return on investment with this range of generators. All you need is a pre-treated compressed air system, and you're set to produce nitrogen quickly and cost-effectively. Make the smart choice today and join the many satisfied users of the nano NMG membrane gas generators.
- Features & Benefits
- Specifications
- Brochure
- Purity: 95 to 99.9%
- Flow Rate: 8 to 2500 scfh
- Added Feature: Wall-mountable System
- All-in-one packages include GF centrifugal water separator, NMD magnetic condensate drain, GFN 1.0 and 0.01-micron coalescing filters, and GFN AC activated carbon filter with no electricity required.
- Composed of hundreds of thousands of hollow fibers separate nitrogen from air through a process known as selective permeation
- Compact and lightweight design provides horizontal or vertical placement in tight spaces with wall mounting brackets included as standard
| Nitrogen Generator Model | Inlet Air Pressure | Air Inlet Requirement and Nitrogen Flow by Model (scfh) Nitrogen (scfm Feed Air) | ||||||
| psig | 99.9%(0.1%) | 99.5%(0.5%) | 99%(1%) | 98%(2%) | 97%(3%) | 96%(4%) | 95%(5%) | |
| NMG 115 | 100 | 8 (1) | 15 (1) | 23 (1) | 29 (1) | 38 (2) | 49 (2) | 56 (2) |
| 125 | 12 (2) | 21 (2) | 32 (2) | 42 (2) | 56 (2) | 67 (3) | 77 (3) | |
| 150 | 13 (2) | 24 (2) | 35 (2) | 45 (2) | 63 (3) | 77 (3) | 91 (3) | |
| 200 | 20 (3) | 35 (3) | 56 (3) | 70 (3) | 95 (4) | 113 (4) | 134 (4) | |
| NMG 130 | 100 | 16 (2) | 30 (2) | 46 (2) | 58 (2) | 76 (4) | 98 (4) | 112 (4) |
| 125 | 24 (4) | 42 (4) | 64 (4) | 84 (4) | 112 (4) | 134 (6) | 154 (6) | |
| 150 | 26 (4) | 48 (4) | 70 (4) | 90 (4) | 126 (6) | 154 (6) | 182 (6) | |
| 200 | 40 (6) | 70 (6) | 112 (6) | 140 (6) | 190 (8) | 226 (8) | 268 (8) | |
| NMG 163 | 100 | 32 (5) | 63 (5) | 84 (5) | 130 (6) | 165 (7) | 204 (8) | 243 (9) |
| 125 | 44 (7) | 87 (7) | 116 (7) | 176 (8) | 226 (9) | 278 (11) | 328 (11) | |
| 150 | 50 (8) | 101 (8) | 134 (8) | 197 (9) | 257 (10) | 314 (12) | 388 (13) | |
| 200 | 73 (12) | 146 (12) | 194 (12) | 293 (13) | 388 (15) | 459 (17) | 529 (18) | |
| NMG 1126 | 100 | 64 (10) | 126 (10) | 168 (10) | 260 (12) | 330 (14) | 408 (16) | 486 (18) |
| 125 | 88 (14) | 174 (14) | 232 (14) | 352 (16) | 452 (18) | 556 (22) | 656 (22) | |
| 150 | 100 (16) | 202 (16) | 268 (16) | 394 (18) | 514 (20) | 628 (24) | 776 (26) | |
| 200 | 146 (24) | 292 (24) | 388 (24) | 586 (26) | 776 (30) | 918 (34) | 1058 (36) | |
| NMG 1317 | 100 | 159 (26) | 317 (26) | 423 (26) | 600 (29) | 776 (32) | 953 (36) | 1130 (39) |
| 125 | 212 (35) | 424 (35) | 565 (34) | 812 (38) | 1059 (43) | 1306 (48) | 1518 (52) | |
| 150 | 238 (40) | 476 (40) | 635 (38) | 918 (41) | 1200 (48) | 1447 (52) | 1730 (58) | |
| 200 | 357 (60) | 715 (60) | 953 (57) | 1341 (60) | 1765 (70) | 2154 (78) | 2542 (85) | |
| Specifications | |
| Inlet & outlet connections | ½” NPT |
| Design operating pressure range | 100 to 200 psig |
| Design operating temperature range | 41 to 113°F |
| Pressure drop | 7 to 10 psig |
(1) This information is for general information purposes only. For additional technical specifications, refer to the product brochure, technical data sheets, and/or user guides. Technical specifications are subject to change.